Electric showers and electric cookers both require their own dedicated high-current circuit โ€” this is not a job for a handyman or a DIY enthusiast. Brad Neil Electrical installs and connects electric showers and cookers across Surrey to the correct specification, with full certification and Part P notification included.

Why It Matters

Signs You May Need This Service

๐Ÿšฟ

New electric shower

Installing a new electric shower requires a dedicated circuit from the consumer unit, sized correctly for the shower's kW rating.

๐Ÿณ

New cooker connection

Electric cookers and range cookers need a dedicated 32A or 45A circuit and a cooker control unit โ€” not a standard socket.

๐Ÿ”„

Replacing an existing unit

Even a like-for-like shower or cooker replacement should be done by a qualified electrician to confirm the existing circuit is still adequate.

๐Ÿ“‹

Certification required

All shower and cooker circuits must be notified under Part P of the Building Regulations โ€” we handle this as part of the job.

The Service

What's Included

  • โœ“Assessment of your existing supply and consumer unit capacity
  • โœ“New dedicated circuit installed from the consumer unit
  • โœ“Correct cable sizing calculated for the appliance rating
  • โœ“Shower pull cord or cooker control unit supplied and fitted
  • โœ“Connection and testing of the appliance
  • โœ“Electrical Installation Certificate (EIC) issued
  • โœ“Part P notification to your local authority
๐Ÿ…

All work carried out by a NICEIC registered Domestic Installer and fully certified to BS 7671 Wiring Regulations.

FAQs

Common Questions

Can I connect a new shower to an existing circuit?

No โ€” electric showers must have their own dedicated circuit. Sharing a circuit with other loads is unsafe and non-compliant with BS 7671.

What size circuit does an electric shower need?

This depends on the shower's kW rating. A 9.5kW shower typically needs a 40A or 45A circuit โ€” we will size it correctly for your specific unit.

Do I need a new consumer unit for a shower?

Not necessarily, but the consumer unit must have a spare way for the new circuit. We will check this during the quotation visit and advise accordingly.

Can you install a shower in a bathroom?

Yes โ€” bathroom electrical installations must comply with the zone regulations in BS 7671, which we are fully trained and qualified to work to.

You May Also Need

Related Services

Coverage

This service is available across: Woking, Knaphill, Bisley, Chobham, Lightwater, Camberley, Frimley, Bagshot, Brookwood, Addlestone, Walton-on-Thames, Weybridge, Long Ditton, Thames Ditton, Surbiton, Esher, Cobham, Kingston upon Thames and surrounding areas.

View all areas covered โ†’

Ready to Book?

Call or message for a free, no-obligation quote. Brad will assess your requirements and provide a clear, honest price with no hidden charges.

Get a Quote07415 834215